5.1. 单寄存器浓度读取 01 03 00 06 00 01 64 0B 5.2. 多通道单寄存器浓度读取 01 03 20 00 00 04 4F C9 5.3. 多寄存器浓度+报警状态读取 01 03 00 05 00 03 15 CA 5.4. 所有参数读取 01 03 00 05 00 0E D4 0F 5.1. 单寄存器浓度读取 01路: 01 03 00 06 00 01 64 0B 返回:01 03 02 00 00 B8 44 5.3. 多寄存器浓度+报警状态读取 01路: 01 03 00 05 00 03 15 CA 返回: 01 03 06 00 00 00 00 00 00 21 75 02路: 02 03 00 05 00 03 15 F9 返回: 02 03 06 00 00 00 09 00 00 E5 87 02 03 06 00 00 03 E8 00 02 34 34 03路: 03 03 00 05 00 03 14 28 返回: 03 03 06 00 00 00 03 00 00 C8 15 04路: 04 03 00 05 00 03 15 9F 返回: 04 03 06 00 00 00 03 00 00 EE 25 05路: 05 03 00 05 00 03 14 4E 返回: 06路: 06 03 00 05 00 03 14 7D 返回: 07路: 07 03 00 05 00 03 15 AC 返回: 08路: 08 03 00 05 00 03 15 53 返回: 5.4. 所有参数读取(用这个轮询) 01路: 01 03 00 05 00 0E D4 0F 返回:01 03 1C 00 00 00 00 00 00 45 58 00 00 00 00 00 01 00 FF 00 00 C8 00 00 00 F4 01 00 00 00 00 61 2F 02路: 02 03 00 05 00 0E D4 3C 返回:02 03 1C 00 00 00 08 00 00 45 58 00 00 00 00 00 01 00 FF 00 00 00 C8 00 00 01 F4 00 00 00 00 50 C7 crc计算方式: 在线计算 http://www.ip33.com/crc.html 选CRC-16/MODBUS 算出的两个字节互调即是 01路:01 03 00 02 00 01 25 CA 返回:01 03 02 08 24 BF 9F 02路:01 03 00 03 00 01 74 0A 返回:01 03 02 08 24 BF 9F 03路:01 03 00 04 00 01 74 0A 返回:01 03 02 08 25 7E 5F 04路:01 03 00 05 00 01 94 0B 返回:01 03 02 08 26 3E 5E